mirror of
https://github.com/Genaker/LoraSA.git
synced 2026-03-28 17:42:59 +01:00
add feature
This commit is contained in:
59
README.md
59
README.md
@@ -55,13 +55,70 @@ Power Bins: 0000,0000,0000,0000,0000,0000,0000,0000,0000,0000,0000,0000,0000,000
|
||||
|
||||
The spectrum analyzer performs power measurements in the configured bandwidth.
|
||||
|
||||
The X-axis represents frequency in MHz and Y-axis displays actual received power.
|
||||
The X-axis represents frequency in MHz, and the Y-axis displays actually received power.
|
||||
In the example above, the frequency span goes from 850 MHz to 950 MHz (that is a 100MHz range), and
|
||||
the visual amplitude goes from -11 dBm to -110(-139) according to the datasheet(High sensitivity: down to -148dBm) dBm.
|
||||
|
||||
To show the results in a plot, run the Python script
|
||||
RadioLib/extras/SX126x_Spectrum_Scan/SpectrumScan.py
|
||||
|
||||
# Features
|
||||
## Multiple Ranges Scan
|
||||
Disabled By Default
|
||||
```
|
||||
// Feature to scan diapazones. Other frequency settings will be ignored.
|
||||
int SCAN_DIAPAZONES[] = {};
|
||||
//int SCAN_DIAPAZONES[] = {850890, 920950};
|
||||
```
|
||||
To Enable Add/ uncomment an array of the frequencies
|
||||
```
|
||||
int SCAN_DIAPAZONES[] = {850890, 920950};
|
||||
```
|
||||
where 850890 stands for 950-890Mhz range
|
||||
920950 - 920-890Mhz
|
||||
Other settings will be ignored if **Multiple Ranges Scan** is enabled.
|
||||
|
||||
## Waterfall
|
||||
Waterfall showed only on One Page Scan
|
||||
to disable - un comment this line
|
||||
```
|
||||
#define WATERFALL_ENABLED true
|
||||
```
|
||||
Waterfall shows the last **N** = SCREAN_HEIGHT (64) - WATERFALL_START(37) - 8 (part of the STATUS_TEXT_TOP) = **19** signal detection that excited set signal level
|
||||
|
||||
## Multi Screen Scan
|
||||
Single screen scan for now has **RANGE / 128** resolution.
|
||||
Multi-page scan can be adjusted to how many MHz per page you wanna scan
|
||||
|
||||
```
|
||||
// frequency range in MHz to scan
|
||||
#define FREQ_BEGIN 850
|
||||
// TODO: if % RANGE_PER_PAGE != 0
|
||||
#define FREQ_END 950
|
||||
|
||||
// Feature to scan diapazones. Other frequency settings will be ignored.
|
||||
int SCAN_DIAPAZONES[] = {};
|
||||
// int SCAN_DIAPAZONES[] = {850890, 920950};
|
||||
|
||||
// MHZ per page
|
||||
//To put everething into one page set RANGE_PER_PAGE = FREQ_END - 800
|
||||
unsigned int RANGE_PER_PAGE = FREQ_END - FREQ_BEGIN; // FREQ_END - FREQ_BEGIN
|
||||
//To Enable Multi Screen scan
|
||||
// unsigned int RANGE_PER_PAGE = 50;
|
||||
// Default Range on Menu Button Switch
|
||||
#define DEFAULT_RANGE_PER_PAGE = 50;
|
||||
|
||||
```
|
||||
To enable Multi-page by default set **RANGE_PER_PAGE** less than **FREQ_END - FREQ_BEGIN**;
|
||||
Switch to multi-page during regular One Screen application run. Restart the ESP32 on screen after the logo press the P button.
|
||||
|
||||
## Mute Autio Notifications
|
||||
Restart ESP32, and on the logo display, press the P button.
|
||||
|
||||
## Pause Execution
|
||||
Press P for more than 2 seconds. Execution will pause, and the scan's current Mhz position will be shown on the display.
|
||||
If less, ESP32 will turn off. Fast pressing(less than 0.5 second) P button changes the notification level
|
||||
|
||||
# VSCode Platform.IO development env installation
|
||||
1. Install VSCode
|
||||
2. install Platfor.IO extension
|
||||
|
||||
Reference in New Issue