export const BATTERY_DISPLAY_CHANGE_EVENT = 'remoteterm-battery-display-change';
// Meshtastic default OCV table (meshtastic/firmware src/power.h)
const OCV_TABLE: [number, number][] = [
[4190, 100],
[4050, 90],
[3990, 80],
[3890, 70],
[3800, 60],
[3720, 50],
[3630, 40],
[3530, 30],
[3420, 20],
[3300, 10],
[3100, 0],
];
export function mvToPercent(mv: number): number {
if (mv >= OCV_TABLE[0][0]) return 100;
if (mv <= OCV_TABLE[OCV_TABLE.length - 1][0]) return 0;
for (let i = 0; i < OCV_TABLE.length - 1; i++) {
const [highMv, highPct] = OCV_TABLE[i];
const [lowMv, lowPct] = OCV_TABLE[i + 1];
if (mv >= lowMv)
return Math.round(lowPct + ((mv - lowMv) / (highMv - lowMv)) * (highPct - lowPct));
}
return 0;
}
export function formatBatteryLabel(
mv: number,
showPercent: boolean,
showVoltage: boolean
): string | null {
if (!showPercent && !showVoltage) return null;
const pct = mvToPercent(mv);
if (showPercent && showVoltage) return `${pct}% (${mv}mV)`;
if (showPercent) return `${pct}%`;
return `${mv}mV`;
}
const PERCENT_KEY = 'remoteterm-show-battery-percent';
const VOLTAGE_KEY = 'remoteterm-show-battery-voltage';
export function getShowBatteryPercent(): boolean {
try {
return localStorage.getItem(PERCENT_KEY) === 'true';
} catch {
return false;
}
}
export function setShowBatteryPercent(enabled: boolean): void {
try {
if (enabled) {
localStorage.setItem(PERCENT_KEY, 'true');
} else {
localStorage.removeItem(PERCENT_KEY);
}
} catch {
// localStorage may be unavailable
}
}
export function getShowBatteryVoltage(): boolean {
try {
return localStorage.getItem(VOLTAGE_KEY) === 'true';
} catch {
return false;
}
}
export function setShowBatteryVoltage(enabled: boolean): void {
try {
if (enabled) {
localStorage.setItem(VOLTAGE_KEY, 'true');
} else {
localStorage.removeItem(VOLTAGE_KEY);
}
} catch {
// localStorage may be unavailable
}
}