Perry MosbacherandClaude Opus 5 19ab3df5fc test: stop the suite killing itself part-way through
`RepeaterDaemon._shutdown` arms an exit watchdog -- a `threading.Timer` that
calls `os._exit(0)` after `SHUTDOWN_EXIT_GRACE_S` (5 s). That is right in
production: it guarantees SIGTERM is honoured.

`test_run_starts_http_and_handles_dispatcher_cancelled_gracefully` awaits
`daemon.run()`, whose `finally` reaches `_shutdown()`, so it armed a real
watchdog and returned. Five seconds later the timer fired and took the whole
pytest process down.

The failure mode is what makes this expensive: `os._exit(0)` exits with **status
zero**. pytest produces no summary line and a truncated progress bar, so the run
looks like it simply ended -- CI reads exit 0 as green on a run that never
finished, and any failure after that point is invisible. Locally the suite
appeared to hang at ~77% with no failures reported; it was actually being killed
there.

It also misattributes itself. The test blamed is whichever happened to be
running five seconds later, so it moves between runs
(`test_route_login_server_companion_only_skips_login_helper` and
`test_route_login_server_hash_collision_offers_to_both` on two runs here) and
never points at the cause. Finding it needed wrapping `_arm_exit_watchdog` to
log the arming test.

Two changes:

- Patch `_arm_exit_watchdog` for that test, matching the guard the shutdown
  tests in `test_main_py_coverage.py` already use.
- Add `tests/conftest.py` with an autouse fixture that fails any test leaving a
  live `shutdown-watchdog` timer, and cancels it. This blames the responsible
  test at the moment it leaks, rather than an unrelated one later. Verified it
  catches the original bug: reverting the one-line fix turns the silent
  process-kill into a teardown error naming the right test.

`test_exit_watchdog_is_a_daemon_timer_that_forces_exit` is unaffected -- it sets
a 0.05 s grace and asserts on a patched `os._exit` before returning, so it
leaves nothing behind.

With this the suite runs to completion: 3 failed, 1580 passed. Those 3 are
pre-existing on `dev` and unrelated.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-02 23:14:35 -04:00

56 lines
1.9 KiB
Python

"""Shared test guards.
`RepeaterDaemon._shutdown` arms an exit watchdog: a `threading.Timer` that calls
`os._exit(0)` once `SHUTDOWN_EXIT_GRACE_S` has elapsed. That is correct in
production -- it guarantees SIGTERM is honoured -- but a test that reaches
`_shutdown` without patching it leaves a live timer behind. When it fires, five
seconds later, it takes the whole pytest process down **with status 0**, part
way through an unrelated test.
The damage is that it looks like success: pytest exits 0 with no summary line
and a truncated progress bar, so CI reports green on a run that never finished
and any failure after that point is invisible. The test blamed in the output is
whichever happened to be running when the timer fired, so it moves between runs
and does not point at the cause.
The autouse fixture below fails the *responsible* test instead, at the moment it
leaks the timer.
"""
import threading
import pytest
_WATCHDOG_NAME = "shutdown-watchdog"
def _live_watchdogs():
return [t for t in threading.enumerate() if t.name == _WATCHDOG_NAME and t.is_alive()]
@pytest.fixture(autouse=True)
def no_leaked_exit_watchdog():
"""Fail any test that leaves a live shutdown-exit watchdog behind.
Patch it out when the code under test reaches `_shutdown`:
with patch.object(daemon, "_arm_exit_watchdog"):
await daemon.run()
or, when the watchdog itself is what you are testing, keep the grace short
and assert on a patched `repeater.main.os._exit` before the test returns.
"""
yield
leaked = _live_watchdogs()
for timer in leaked:
timer.cancel()
if leaked:
pytest.fail(
"test left %d live '%s' timer(s) running. Each one calls os._exit(0) "
"when it fires and will kill the pytest process mid-run, with exit "
"status 0 and no summary. Patch _arm_exit_watchdog for this test."
% (len(leaked), _WATCHDOG_NAME),
pytrace=False,
)