Files
mc-webui/app
MarekWo 92f5a7edca feat(repeaters): Settings tool (stage 7)
- GET/POST /api/repeaters/<pk>/settings?section=X: sequential text-CLI
  get/set batches via repeater_cmd_wait; per-field values/errors on read,
  per-field ok|failed|reboot_required classification on write (reply
  starting ok/password now = ok, mention of reboot = reboot_required);
  admin-gated via new _require_repeater_admin helper (also reused by /cli)
- Settings pane: accordion with 8 sections (Basic, Radio, Location,
  Features, Network health, Advertisement, Operator info, Advanced),
  lazy-loaded on first expand (each field is one mesh round-trip),
  per-section Refresh/Apply, dirty tracking with header badges
- Field types: on/off switches, 0/1 switches, select (loop.detect),
  composite radio (freq,bw,sf,cr) with reboot warning + confirm dialog,
  write-only admin password (updates the saved password on success),
  owner.info textarea with pipe-to-newline mapping
- Failed writes keep the field dirty and surface the firmware reply
  (e.g. "Error: interval range is 60-240 minutes") under the input
- Strip "%" suffix when loading number fields (get dutycycle -> "70.0%")

Verified live against PL-KRA Wegrzce 2: all 8 sections read cleanly,
flood.max 64->63->64 write round-trip, firmware range rejection surfaced
per-field, radio confirm-cancel path, dutycycle % parsing.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-18 14:43:16 +02:00
..