Situation
Remote or inaccessible igate. Power failure and subsequent restoration
Issue
If the wifi AP takes longer than the igate to recover on power restoration, the igate does not connect to the recovered AP.
Possible solutions
Parameter in the config file to specify a delay on boot before attemting to connect to wifi
If the wifi does not connect and the autoAP is not used, then go back and retry the wifi connection.
env: heltec_wifi_lora_32_V3
Many thanks for your incredible work on this software.
73 John GW4BVE
Hi Ricardo
Situation
Remote or inaccessible igate. Power failure and subsequent restoration
Issue
If the wifi AP takes longer than the igate to recover on power restoration, the igate does not connect to the recovered AP.
Possible solutions
1. Parameter in the config file to specify a delay on boot before attemting to connect to wifi
2. If the wifi does not connect and the autoAP is not used, then go back and retry the wifi connection.
env: heltec_wifi_lora_32_V3
Many thanks for your incredible work on this software.
73 John GW4BVE
<!-- github-sync-id:2375804686 -->
but this is enabled over VSCODE firmware upload only (for now) please test
Hi, on the firmware there is a delay:
LoRa_APRS_iGate.cpp line 58
but this is enabled over VSCODE firmware upload only (for now) please test
<!-- github-comment-id:2192171973 -->
Recovery after power failure is now perfect. The switch and AP come up then the igate connects. I only need a 1 min delay.
I have closed the issue but would it be possible to move this configuration to the igate_config.json file?
Many thanks Ricardo
73 John GW4BVE
Recovery after power failure is now perfect. The switch and AP come up then the igate connects. I only need a 1 min delay.
I have closed the issue but would it be possible to move this configuration to the igate_config.json file?
Many thanks Ricardo
73 John GW4BVE
<!-- github-comment-id:2198541491 -->
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Hi Ricardo
Situation
Remote or inaccessible igate. Power failure and subsequent restoration
Issue
If the wifi AP takes longer than the igate to recover on power restoration, the igate does not connect to the recovered AP.
Possible solutions
env: heltec_wifi_lora_32_V3
Many thanks for your incredible work on this software.
73 John GW4BVE
Hi, on the firmware there is a delay:
LoRa_APRS_iGate.cpp line 58
but this is enabled over VSCODE firmware upload only (for now) please test
OK many thanks Ricardo. I will edit and test. I do all the uploads via Vscode.
73 John GW4BVE
Recovery after power failure is now perfect. The switch and AP come up then the igate connects. I only need a 1 min delay.
I have closed the issue but would it be possible to move this configuration to the igate_config.json file?
Many thanks Ricardo
73 John GW4BVE
i will try to add this to next release ;)